{"id":10122,"date":"2025-12-05T15:46:14","date_gmt":"2025-12-05T14:46:14","guid":{"rendered":"https:\/\/lubeteam.it\/prodotto\/ufi-fta-ftb-transmission-filters\/"},"modified":"2025-12-23T11:04:35","modified_gmt":"2025-12-23T10:04:35","slug":"ufi-fta-ftb-transmission-filters","status":"publish","type":"product","link":"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/","title":{"rendered":"UFI FTA \u2013 FTB Transmission Filters"},"content":{"rendered":"<h3><strong>Filters for Hydrostatic Transmissions FTA and FTB Series: Protection and Reliability<\/strong><\/h3>\n<p>The FTA\u2013FTB series by UFI Filters represents a specialized solution for filtration in hydrostatic transmission circuits. These filters are designed to handle combined suction and return flows, effectively protecting critical components such as boost pumps and emergency valves.<\/p>\n<h3><strong>Configurations and Operating Principle<\/strong><\/h3>\n<p>The range is divided into two main versions to suit different system requirements:<\/p>\n<ul>\n<li><strong>FTA Series:<\/strong> Featuring an internal bypass valve.<\/li>\n<li><strong>FTB Series:<\/strong> Equipped with an external bypass valve.<\/li>\n<\/ul>\n<p>The system is designed to filter the oil returning to the tank while simultaneously supplying the suction line of the boost pump, reducing the risk of cavitation and ensuring clean oil to the closed-loop circuit.<\/p>\n<h3><strong>Construction Features and Materials<\/strong><\/h3>\n<p>The filters are built to withstand harsh operating conditions:<\/p>\n<ul>\n<li><strong>Head:<\/strong> Made of aluminum alloy.<\/li>\n<li><strong>Cover:<\/strong> Polyamide for size 2 (FTA\/FTB 23) and aluminum alloy for size 3 (FTA\/FTB 31-32-33).<\/li>\n<li><strong>Bowl:<\/strong> Steel, ensuring structural robustness.<\/li>\n<li><strong>Seals:<\/strong> Standard NBR (Nitrile).<\/li>\n<\/ul>\n<h3><strong>Filter Elements and Media<\/strong><\/h3>\n<p>The series uses <strong>FormulaUFI.MICRON<\/strong> technology with inorganic glass fiber media, specifically designed to ensure high cleanliness standards (\u00df &gt; 1,000) even at high differential pressures (\u0394p 2 MPa \/ 20 bar). Available filtration ratings are:<\/p>\n<ul>\n<li><strong>FC:<\/strong> 12 \u00b5m.<\/li>\n<li><strong>FS:<\/strong> 16 \u00b5m.<\/li>\n<\/ul>\n<h3><strong>Accessories and Valve Options<\/strong><\/h3>\n<p>The filters can be configured with various valve options to optimize circuit performance:<\/p>\n<ul>\n<li><strong>Option A:<\/strong> Pressurization valve (recommended for horizontal mounting).<\/li>\n<li><strong>Option B:<\/strong> Pressurization valve + drain port (recommended for vertical mounting).<\/li>\n<li><strong>Options C and D:<\/strong> Include a suction bypass with a 125 \u00b5m strainer that protects the emergency valve in the event of a temporary lack of oil at the boost pump suction.<\/li>\n<\/ul>\n<h3>Technical summary table of the main characteristics of UFI FTA \u2013 FTB Transmission Filters<\/h3>\n<p>&nbsp;<\/p>\n<div style=\"width: 100%; overflow-x: auto;\">\n<table style=\"width: 100%; border-collapse: collapse;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2;\">Characteristic<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left; background-color: #f2f2f2;\">Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Filter Type<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Hydrostatic transmission filter<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Maximum Flow Rate (Qmax)<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">240 l\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Max Operating Pressure<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">1 MPa (10 bar)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Element Collapse Pressure<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">1 MPa (10 bar)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Bypass Valve Setting<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">250 kPa (2.5 bar) \u00b1 10%<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Head Material<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Aluminum alloy<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Bowl Material<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Steel<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Filter Media<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">FormulaUFI.MICRON (12 \u00b5m, 16 \u00b5m)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Operating Temperature<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">From -25\u00b0C to +110\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Fluid Compatibility<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">HH-HL-HM-HV-HTG (ISO 6743\/4)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Bypass Options<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Internal (FTA) or External (FTB)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p><strong>UFI FTA \u2013 FTB transmission filters<\/strong> are specifically designed for hydrostatic transmission circuits, ensuring protection of boost pumps. Available in configurations with internal bypass (FTA) or external bypass (FTB), they support a maximum flow rate of 240 l\/min and an operating pressure of 1 MPa (10 bar). Equipped with high-efficiency FormulaUFI.MICRON filter media and pressurization valve options, they ensure high performance and optimal contamination control.<\/p>\n","protected":false},"featured_media":9921,"template":"","meta":[],"product_brand":[],"product_cat":[103,105,407],"product_tag":[288],"class_list":{"0":"post-10122","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-filters","7":"product_cat-hydraulic-filters","8":"product_cat-ufi-transmission-filters","9":"product_tag-ufi-filters","10":"yith_product_brand-ufi-filters","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.5 (Yoast SEO v26.3) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>UFI FTA \u2013 FTB Transmission Filters \u2013 LubeTeam Hydraulic<\/title>\n<meta name=\"description\" content=\"UFI FTA-FTB hydrostatic transmission filters. Flow rate 240 l\/min, pressure 10 bar. Internal or external bypass and FormulaUFI filter media.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"UFI FTA \u2013 FTB Transmission Filters\" \/>\n<meta property=\"og:description\" content=\"UFI FTA-FTB hydrostatic transmission filters. Flow rate 240 l\/min, pressure 10 bar. Internal or external bypass and FormulaUFI filter media.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/\" \/>\n<meta property=\"og:site_name\" content=\"LubeTeam Hydraulic\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/lubeteam\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-23T10:04:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/lubeteam.it\/wp-content\/uploads\/2025\/12\/fta-ftb.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/\",\"url\":\"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/\",\"name\":\"UFI FTA \u2013 FTB Transmission Filters \u2013 LubeTeam Hydraulic\",\"isPartOf\":{\"@id\":\"https:\/\/lubeteam.it\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/lubeteam.it\/wp-content\/uploads\/2025\/12\/fta-ftb.webp\",\"datePublished\":\"2025-12-05T14:46:14+00:00\",\"dateModified\":\"2025-12-23T10:04:35+00:00\",\"description\":\"UFI FTA-FTB hydrostatic transmission filters. Flow rate 240 l\/min, pressure 10 bar. Internal or external bypass and FormulaUFI filter media.\",\"breadcrumb\":{\"@id\":\"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/#primaryimage\",\"url\":\"https:\/\/lubeteam.it\/wp-content\/uploads\/2025\/12\/fta-ftb.webp\",\"contentUrl\":\"https:\/\/lubeteam.it\/wp-content\/uploads\/2025\/12\/fta-ftb.webp\",\"width\":1080,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/lubeteam.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Product\",\"item\":\"https:\/\/lubeteam.it\/en\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"UFI FTA \u2013 FTB Transmission Filters\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/lubeteam.it\/#website\",\"url\":\"https:\/\/lubeteam.it\/\",\"name\":\"LubeTeam Hydraulic\",\"description\":\"HYDRAULIC COMPONENTS &amp; FLUID CONTAMINATION CONTROL\",\"publisher\":{\"@id\":\"https:\/\/lubeteam.it\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/lubeteam.it\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/lubeteam.it\/#organization\",\"name\":\"LubeTeam Hydraulic\",\"url\":\"https:\/\/lubeteam.it\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/lubeteam.it\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/lubeteam.it\/wp-content\/uploads\/2022\/12\/logo.webp\",\"contentUrl\":\"https:\/\/lubeteam.it\/wp-content\/uploads\/2022\/12\/logo.webp\",\"width\":344,\"height\":85,\"caption\":\"LubeTeam Hydraulic\"},\"image\":{\"@id\":\"https:\/\/lubeteam.it\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/lubeteam\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"UFI FTA \u2013 FTB Transmission Filters \u2013 LubeTeam Hydraulic","description":"UFI FTA-FTB hydrostatic transmission filters. Flow rate 240 l\/min, pressure 10 bar. Internal or external bypass and FormulaUFI filter media.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/","og_locale":"en_US","og_type":"article","og_title":"UFI FTA \u2013 FTB Transmission Filters","og_description":"UFI FTA-FTB hydrostatic transmission filters. Flow rate 240 l\/min, pressure 10 bar. Internal or external bypass and FormulaUFI filter media.","og_url":"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/","og_site_name":"LubeTeam Hydraulic","article_publisher":"https:\/\/www.facebook.com\/lubeteam","article_modified_time":"2025-12-23T10:04:35+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/lubeteam.it\/wp-content\/uploads\/2025\/12\/fta-ftb.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/","url":"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/","name":"UFI FTA \u2013 FTB Transmission Filters \u2013 LubeTeam Hydraulic","isPartOf":{"@id":"https:\/\/lubeteam.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/#primaryimage"},"image":{"@id":"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/#primaryimage"},"thumbnailUrl":"https:\/\/lubeteam.it\/wp-content\/uploads\/2025\/12\/fta-ftb.webp","datePublished":"2025-12-05T14:46:14+00:00","dateModified":"2025-12-23T10:04:35+00:00","description":"UFI FTA-FTB hydrostatic transmission filters. Flow rate 240 l\/min, pressure 10 bar. Internal or external bypass and FormulaUFI filter media.","breadcrumb":{"@id":"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/#primaryimage","url":"https:\/\/lubeteam.it\/wp-content\/uploads\/2025\/12\/fta-ftb.webp","contentUrl":"https:\/\/lubeteam.it\/wp-content\/uploads\/2025\/12\/fta-ftb.webp","width":1080,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/lubeteam.it\/en\/product\/ufi-fta-ftb-transmission-filters\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/lubeteam.it\/en\/"},{"@type":"ListItem","position":2,"name":"Product","item":"https:\/\/lubeteam.it\/en\/products\/"},{"@type":"ListItem","position":3,"name":"UFI FTA \u2013 FTB Transmission Filters"}]},{"@type":"WebSite","@id":"https:\/\/lubeteam.it\/#website","url":"https:\/\/lubeteam.it\/","name":"LubeTeam Hydraulic","description":"HYDRAULIC COMPONENTS &amp; FLUID CONTAMINATION CONTROL","publisher":{"@id":"https:\/\/lubeteam.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lubeteam.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/lubeteam.it\/#organization","name":"LubeTeam Hydraulic","url":"https:\/\/lubeteam.it\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lubeteam.it\/#\/schema\/logo\/image\/","url":"https:\/\/lubeteam.it\/wp-content\/uploads\/2022\/12\/logo.webp","contentUrl":"https:\/\/lubeteam.it\/wp-content\/uploads\/2022\/12\/logo.webp","width":344,"height":85,"caption":"LubeTeam Hydraulic"},"image":{"@id":"https:\/\/lubeteam.it\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/lubeteam"]}]}},"df_price":"","df_sale_price":"","df_regular_price":"","df_image_link":"https:\/\/lubeteam.it\/wp-content\/uploads\/2025\/12\/fta-ftb-300x300.webp","_links":{"self":[{"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/product\/10122","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/media\/9921"}],"wp:attachment":[{"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/media?parent=10122"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/product_brand?post=10122"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/product_cat?post=10122"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/product_tag?post=10122"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}