{"id":5584,"date":"2023-07-10T10:24:49","date_gmt":"2023-07-10T08:24:49","guid":{"rendered":"https:\/\/lubeteam.it\/?post_type=product&#038;p=5584"},"modified":"2025-11-14T11:54:20","modified_gmt":"2025-11-14T10:54:20","slug":"p04-pumps","status":"publish","type":"product","link":"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/","title":{"rendered":"P04 pumps"},"content":{"rendered":"<div class=\"elementor-element elementor-element-1dc7fb1 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"1dc7fb1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"elementor-text-editor elementor-clearfix\">\n<h3 data-start=\"421\" data-end=\"458\">Operation and Application Range<\/h3>\n<p data-start=\"459\" data-end=\"871\">The <strong data-start=\"462\" data-end=\"482\">Berarma P04 Pumps<\/strong> are <strong data-start=\"488\" data-end=\"530\">variable displacement vane pumps<\/strong> with a <strong data-start=\"535\" data-end=\"574\">hydraulic pressure compensator<\/strong>. They instantly adjust the flow rate to match the circuit demand: once the <strong data-start=\"665\" data-end=\"690\">set pressure<\/strong> is reached, the flow decreases until it reaches zero, maintaining an almost constant pressure; with zero demand, the pump only delivers the oil necessary to compensate for leakages and pilot flows.<\/p>\n<h3 data-start=\"873\" data-end=\"902\">Standard Features<\/h3>\n<ul data-start=\"903\" data-end=\"1395\">\n<li data-start=\"903\" data-end=\"988\">\n<p data-start=\"905\" data-end=\"988\"><strong data-start=\"905\" data-end=\"940\">Maximum operating pressure:<\/strong> 210 bar; <strong data-start=\"950\" data-end=\"972\">adjustment range:<\/strong> 20 \u00f7 210 bar.<\/p>\n<\/li>\n<li data-start=\"989\" data-end=\"1064\">\n<p data-start=\"991\" data-end=\"1064\"><strong data-start=\"991\" data-end=\"1015\">Nominal displacement:<\/strong> 8 cm\u00b3\/rev; <strong data-start=\"1028\" data-end=\"1042\">actual:<\/strong> 8.4 cm\u00b3\/rev (\u00b13%).<\/p>\n<\/li>\n<li data-start=\"1065\" data-end=\"1102\">\n<p data-start=\"1067\" data-end=\"1102\"><strong data-start=\"1067\" data-end=\"1090\">Flow at 1450 rpm:<\/strong> 12 l\/min.<\/p>\n<\/li>\n<li data-start=\"1103\" data-end=\"1228\">\n<p data-start=\"1105\" data-end=\"1228\"><strong data-start=\"1105\" data-end=\"1129\">Speed range:<\/strong> 350 \u00f7 2000 rpm (ensure proper inlet line sizing at high speeds to avoid cavitation).<\/p>\n<\/li>\n<li data-start=\"1229\" data-end=\"1353\">\n<p data-start=\"1231\" data-end=\"1353\"><strong data-start=\"1231\" data-end=\"1254\">Direction of rotation:<\/strong> right-hand (clockwise) viewed from shaft side; <strong data-start=\"1290\" data-end=\"1314\">shaft loads:<\/strong> radial and axial forces not permitted.<\/p>\n<\/li>\n<li data-start=\"1354\" data-end=\"1395\">\n<p data-start=\"1356\" data-end=\"1395\"><strong data-start=\"1356\" data-end=\"1378\">Moment of inertia:<\/strong> 0.000028 kg\u00b7m\u00b2.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"1397\" data-end=\"1429\">Fluids, Viscosity and Cleanliness<\/h3>\n<p data-start=\"1430\" data-end=\"2020\">Approved fluids: <strong data-start=\"1446\" data-end=\"1452\">HM<\/strong> (ISO 6743-4), <strong data-start=\"1467\" data-end=\"1474\">HLP<\/strong> (DIN 51524-2), <strong data-start=\"1490\" data-end=\"1498\">HEES<\/strong> (ISO 15380) and <strong data-start=\"1513\" data-end=\"1520\">HFD<\/strong> (ISO 12922) with <strong data-start=\"1537\" data-end=\"1562\">FPM-Viton seals<\/strong> and <strong data-start=\"1565\" data-end=\"1581\">Pmax 160 bar<\/strong>; <strong data-start=\"1583\" data-end=\"1590\">HFC<\/strong> (ISO 12922) with <strong data-start=\"1607\" data-end=\"1621\">water &lt;40%<\/strong>, <strong data-start=\"1623\" data-end=\"1642\">NBR seals<\/strong>, <strong data-start=\"1644\" data-end=\"1660\">Pmax 100 bar<\/strong>, <strong data-start=\"1662\" data-end=\"1684\">Vmax 1000 rpm<\/strong>, <strong data-start=\"1686\" data-end=\"1698\">T &lt;40 \u00b0C<\/strong>. <strong data-start=\"1700\" data-end=\"1727\">Operating viscosity:<\/strong> 22 \u00f7 68 cSt; <strong data-start=\"1741\" data-end=\"1776\">at startup (open outlet):<\/strong> max 400 cSt; <strong data-start=\"1790\" data-end=\"1814\">viscosity index:<\/strong> \u2265100 (ISO 2909). <strong data-start=\"1832\" data-end=\"1870\">Fluid temperature at inlet:<\/strong> +15 \u00f7 +60 \u00b0C. <strong data-start=\"1885\" data-end=\"1908\">Maximum contamination:<\/strong> ISO 4406 <strong data-start=\"1918\" data-end=\"1930\">20\/18\/15<\/strong> \u2013 NAS 1638 <strong data-start=\"1942\" data-end=\"1954\">Class 9<\/strong>; <strong data-start=\"1956\" data-end=\"1972\">recommended:<\/strong> ISO 4406 <strong data-start=\"1982\" data-end=\"1994\">18\/16\/13<\/strong> \u2013 NAS 1638 <strong data-start=\"2006\" data-end=\"2018\">Class 7<\/strong>.<\/p>\n<h3 data-start=\"2022\" data-end=\"2054\">Connections, Flanges and Weight<\/h3>\n<p data-start=\"2055\" data-end=\"2310\">Connections <strong data-start=\"2067\" data-end=\"2078\">Gas BSP<\/strong>: <strong data-start=\"2080\" data-end=\"2100\">Suction 3\/8&#8243;<\/strong>, <strong data-start=\"2102\" data-end=\"2118\">Delivery 3\/8&#8243;<\/strong>, <strong data-start=\"2120\" data-end=\"2138\">Drain 1\/4&#8243;<\/strong>. <strong data-start=\"2140\" data-end=\"2155\">\u201cG\u201d flange<\/strong>: European type gear group 1, Gas BSP fittings. <strong data-start=\"2209\" data-end=\"2233\">Single pump weight:<\/strong> <strong data-start=\"2234\" data-end=\"2246\">S 2.9 kg<\/strong> \u00b7 <strong data-start=\"2249\" data-end=\"2261\">R 3.3 kg<\/strong> \u00b7 <strong data-start=\"2264\" data-end=\"2276\">D 3.6 kg<\/strong> \u00b7 <strong data-start=\"2279\" data-end=\"2292\">LR 3.6 kg<\/strong> \u00b7 <strong data-start=\"2295\" data-end=\"2308\">LD 3.9 kg<\/strong>.<\/p>\n<h3 data-start=\"2312\" data-end=\"2358\">Control Variants (Pressure\/Flow)<\/h3>\n<ul data-start=\"2359\" data-end=\"2975\">\n<li data-start=\"2359\" data-end=\"2435\">\n<p data-start=\"2361\" data-end=\"2435\"><strong data-start=\"2361\" data-end=\"2367\">S:<\/strong> single pressure stage (adjustment via screw and locknut).<\/p>\n<\/li>\n<li data-start=\"2436\" data-end=\"2570\">\n<p data-start=\"2438\" data-end=\"2570\"><strong data-start=\"2438\" data-end=\"2444\">R:<\/strong> single stage with <strong data-start=\"2464\" data-end=\"2490\">remote adjustment<\/strong> via remote relief valve (recommended valves 2\u20135 l\/min, tube \u22645 m).<\/p>\n<\/li>\n<li data-start=\"2571\" data-end=\"2682\">\n<p data-start=\"2573\" data-end=\"2682\"><strong data-start=\"2573\" data-end=\"2579\">D:<\/strong> <strong data-start=\"2580\" data-end=\"2610\">dual pressure stage<\/strong>, electrical switching <strong data-start=\"2635\" data-end=\"2645\">24 VDC<\/strong> (<strong data-start=\"2658\" data-end=\"2678\">DIN 43650 type A<\/strong> connector).<\/p>\n<\/li>\n<li data-start=\"2683\" data-end=\"2861\">\n<p data-start=\"2685\" data-end=\"2861\"><strong data-start=\"2685\" data-end=\"2692\">LR:<\/strong> <strong data-start=\"2693\" data-end=\"2709\">Load Sensing<\/strong> in <strong data-start=\"2712\" data-end=\"2730\">single stage<\/strong>, with optional <strong data-start=\"2751\" data-end=\"2777\">remote adjustment<\/strong> (signal \u0394p taken after restrictor; recommended valves 2\u20135 l\/min, tube \u22645 m).<\/p>\n<\/li>\n<li data-start=\"2862\" data-end=\"2975\">\n<p data-start=\"2864\" data-end=\"2975\"><strong data-start=\"2864\" data-end=\"2871\">LD:<\/strong> <strong data-start=\"2872\" data-end=\"2888\">Load Sensing<\/strong> with <strong data-start=\"2891\" data-end=\"2915\">two adjustable stages<\/strong>; <strong data-start=\"2917\" data-end=\"2929\">MIN = \u0394p<\/strong>; switching <strong data-start=\"2944\" data-end=\"2954\">24 VDC<\/strong> (DIN 43650 type A).<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"2977\" data-end=\"3005\">Available Adjustments<\/h3>\n<p data-start=\"3006\" data-end=\"3429\"><strong data-start=\"3006\" data-end=\"3020\">Pressure:<\/strong> increase by turning clockwise (respect ranges; do not alter MIN for R\/LR controls; in LD, MIN equals \u0394p).<br data-start=\"3142\" data-end=\"3145\" \/><strong data-start=\"3145\" data-end=\"3168\">Flow\/displacement:<\/strong> <strong data-start=\"3169\" data-end=\"3193\">mechanical regulator<\/strong> to limit maximum displacement; <strong data-start=\"3230\" data-end=\"3270\">displacement reduction per screw turn:<\/strong> <strong data-start=\"3271\" data-end=\"3287\">5.3 cm\u00b3\/rev<\/strong>; <strong data-start=\"3289\" data-end=\"3311\">minimum displacement:<\/strong> not specified (*). Startup allowed with settings &lt;50% if both pump and system are completely filled with fluid.<\/p>\n<hr data-start=\"3431\" data-end=\"3434\" \/>\n<h3 data-start=\"3436\" data-end=\"3523\"><strong data-start=\"3436\" data-end=\"3523\">Technical Summary Table of the Main Features of Berarma P04 Pumps<\/strong><\/h3>\n<\/div>\n<\/div>\n<\/div>\n<div style=\"width: 100%; overflow-x: auto;\">\n<table style=\"width: 100%; border-collapse: collapse;\">\n<thead>\n<tr>\n<th style=\"text-align: left; padding: 8px; border-bottom: 1px solid #ddd;\">Parameter<\/th>\n<th style=\"text-align: left; padding: 8px; border-bottom: 1px solid #ddd;\">Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Designation \/ Series<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">P04-8<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Nominal displacement (ISO 3662)<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">8 cm\u00b3\/rev<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Actual displacement<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">8.4 cm\u00b3\/rev (\u00b13%)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Flow at 1450 rpm<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">12 l\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Maximum operating pressure<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">210 bar<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Pressure adjustment range<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">20 \u00f7 210 bar<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Maximum drain pressure<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">1 bar<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Inlet pressure<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">0.8 \u00f7 1.5 bar absolute<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Speed range<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">350 \u00f7 2000 rpm<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Direction of rotation<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Right-hand (clockwise) viewed from shaft side<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Shaft loads<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">No radial or axial forces allowed<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Approved fluids<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">HM (ISO 6743-4) \u00b7 HLP (DIN 51524-2) \u00b7 HEES (ISO 15380) \u00b7 HFD (ISO 12922) \u00b7 HFC (ISO 12922)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Seal notes \/ limitations<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">HEES\/HFD: FPM-Viton, Pmax 160 bar \u00b7 HFC: water &lt;40%, NBR, Pmax 100 bar, Vmax 1000 rpm, T &lt;40\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Operating viscosity<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">22 \u00f7 68 cSt<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Viscosity at startup (open outlet)<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">400 cSt max<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Viscosity index (ISO 2909)<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u2265 100<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Fluid temperature at inlet<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">+15 \u00f7 +60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Max acceptable contamination<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">ISO 4406: 20\/18\/15 \u00b7 NAS 1638: Class 9<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Recommended contamination level<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">ISO 4406: 18\/16\/13 \u00b7 NAS 1638: Class 7<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Moment of inertia<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">0.000028 kg\u00b7m\u00b2<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Single pump weight \u2014 Control S<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">2.9 kg<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Single pump weight \u2014 Control R<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">3.3 kg<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Single pump weight \u2014 Control D<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">3.6 kg<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Single pump weight \u2014 Control LR<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">3.6 kg<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Single pump weight \u2014 Control LD<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">3.9 kg<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Pressure\/flow controls<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">S \u00b7 R \u00b7 D \u00b7 LR \u00b7 LD<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Connections<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Suction 3\/8&#8243; Gas BSP \u00b7 Delivery 3\/8&#8243; Gas BSP \u00b7 Drain 1\/4&#8243; Gas BSP<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">Flange \/ Fittings<\/td>\n<td style=\"padding: 8px; border-bottom: 1px solid #eee;\">\u201cG\u201d flange (European gear group 1) \u00b7 Gas BSP<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>P04 pumps<\/strong> are variable displacement vane pumps designed for high operating pressures, equipped with a hydraulic pressure control device that allows the delivered flow to instantly adjust according to the circuit\u2019s demand.<\/p>\n<p>Variable displacement vane pumps are positive displacement pumps; therefore, they deliver a maximum flow rate equivalent to their displacement multiplied by the rotational speed.<\/p>\n<p>The operating pressure is generated by the pressure losses the fluid encounters along its path through the system. When the outlet pressure (in the system) reaches the pump\u2019s set pressure, the delivered flow automatically adjusts to the system\u2019s demand; once this value is reached, the pump reduces its flow down to zero while maintaining an almost constant pressure. Under zero-demand conditions, the pump only delivers oil to compensate for possible leakages and pilot flows.<\/p>\n","protected":false},"featured_media":5586,"template":"","meta":[],"product_brand":[],"product_cat":[116,110],"product_tag":[316],"class_list":{"0":"post-5584","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-berarma-pumps","7":"product_cat-pumps-and-motors","8":"product_tag-berama","10":"first","11":"instock","12":"shipping-taxable","13":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.5 (Yoast SEO v26.3) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>P04 pumps - LTH - LubeTeam Hydraulic<\/title>\n<meta name=\"description\" content=\"Berarma P04 Pumps, variable vane type, 8 cm\u00b3\/rev, up to 210 bar, compact and versatile for high-efficiency hydraulic systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"P04 pumps\" \/>\n<meta property=\"og:description\" content=\"Berarma P04 Pumps, variable vane type, 8 cm\u00b3\/rev, up to 210 bar, compact and versatile for high-efficiency hydraulic systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/\" \/>\n<meta property=\"og:site_name\" content=\"LubeTeam Hydraulic\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/lubeteam\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-14T10:54:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/lubeteam.it\/wp-content\/uploads\/2023\/07\/Pompe-P04-removebg-preview.png\" \/>\n\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/\",\"url\":\"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/\",\"name\":\"P04 pumps - LTH - LubeTeam Hydraulic\",\"isPartOf\":{\"@id\":\"https:\/\/lubeteam.it\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/lubeteam.it\/wp-content\/uploads\/2023\/07\/Pompe-P04-removebg-preview.png\",\"datePublished\":\"2023-07-10T08:24:49+00:00\",\"dateModified\":\"2025-11-14T10:54:20+00:00\",\"description\":\"Berarma P04 Pumps, variable vane type, 8 cm\u00b3\/rev, up to 210 bar, compact and versatile for high-efficiency hydraulic systems.\",\"breadcrumb\":{\"@id\":\"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/#primaryimage\",\"url\":\"https:\/\/lubeteam.it\/wp-content\/uploads\/2023\/07\/Pompe-P04-removebg-preview.png\",\"contentUrl\":\"https:\/\/lubeteam.it\/wp-content\/uploads\/2023\/07\/Pompe-P04-removebg-preview.png\",\"width\":350,\"height\":350,\"caption\":\"Pompe P04\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/lubeteam.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Product\",\"item\":\"https:\/\/lubeteam.it\/en\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"P04 pumps\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/lubeteam.it\/#website\",\"url\":\"https:\/\/lubeteam.it\/\",\"name\":\"LubeTeam Hydraulic\",\"description\":\"HYDRAULIC COMPONENTS &amp; FLUID CONTAMINATION CONTROL\",\"publisher\":{\"@id\":\"https:\/\/lubeteam.it\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/lubeteam.it\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/lubeteam.it\/#organization\",\"name\":\"LubeTeam Hydraulic\",\"url\":\"https:\/\/lubeteam.it\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/lubeteam.it\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/lubeteam.it\/wp-content\/uploads\/2022\/12\/logo.webp\",\"contentUrl\":\"https:\/\/lubeteam.it\/wp-content\/uploads\/2022\/12\/logo.webp\",\"width\":344,\"height\":85,\"caption\":\"LubeTeam Hydraulic\"},\"image\":{\"@id\":\"https:\/\/lubeteam.it\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/lubeteam\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"P04 pumps - LTH - LubeTeam Hydraulic","description":"Berarma P04 Pumps, variable vane type, 8 cm\u00b3\/rev, up to 210 bar, compact and versatile for high-efficiency hydraulic systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/","og_locale":"en_US","og_type":"article","og_title":"P04 pumps","og_description":"Berarma P04 Pumps, variable vane type, 8 cm\u00b3\/rev, up to 210 bar, compact and versatile for high-efficiency hydraulic systems.","og_url":"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/","og_site_name":"LubeTeam Hydraulic","article_publisher":"https:\/\/www.facebook.com\/lubeteam","article_modified_time":"2025-11-14T10:54:20+00:00","og_image":[{"width":350,"height":350,"url":"https:\/\/lubeteam.it\/wp-content\/uploads\/2023\/07\/Pompe-P04-removebg-preview.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/","url":"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/","name":"P04 pumps - LTH - LubeTeam Hydraulic","isPartOf":{"@id":"https:\/\/lubeteam.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/#primaryimage"},"image":{"@id":"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/#primaryimage"},"thumbnailUrl":"https:\/\/lubeteam.it\/wp-content\/uploads\/2023\/07\/Pompe-P04-removebg-preview.png","datePublished":"2023-07-10T08:24:49+00:00","dateModified":"2025-11-14T10:54:20+00:00","description":"Berarma P04 Pumps, variable vane type, 8 cm\u00b3\/rev, up to 210 bar, compact and versatile for high-efficiency hydraulic systems.","breadcrumb":{"@id":"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lubeteam.it\/en\/product\/p04-pumps\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/#primaryimage","url":"https:\/\/lubeteam.it\/wp-content\/uploads\/2023\/07\/Pompe-P04-removebg-preview.png","contentUrl":"https:\/\/lubeteam.it\/wp-content\/uploads\/2023\/07\/Pompe-P04-removebg-preview.png","width":350,"height":350,"caption":"Pompe P04"},{"@type":"BreadcrumbList","@id":"https:\/\/lubeteam.it\/en\/product\/p04-pumps\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/lubeteam.it\/en\/"},{"@type":"ListItem","position":2,"name":"Product","item":"https:\/\/lubeteam.it\/en\/products\/"},{"@type":"ListItem","position":3,"name":"P04 pumps"}]},{"@type":"WebSite","@id":"https:\/\/lubeteam.it\/#website","url":"https:\/\/lubeteam.it\/","name":"LubeTeam Hydraulic","description":"HYDRAULIC COMPONENTS &amp; FLUID CONTAMINATION CONTROL","publisher":{"@id":"https:\/\/lubeteam.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lubeteam.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/lubeteam.it\/#organization","name":"LubeTeam Hydraulic","url":"https:\/\/lubeteam.it\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lubeteam.it\/#\/schema\/logo\/image\/","url":"https:\/\/lubeteam.it\/wp-content\/uploads\/2022\/12\/logo.webp","contentUrl":"https:\/\/lubeteam.it\/wp-content\/uploads\/2022\/12\/logo.webp","width":344,"height":85,"caption":"LubeTeam Hydraulic"},"image":{"@id":"https:\/\/lubeteam.it\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/lubeteam"]}]}},"df_price":"","df_sale_price":"","df_regular_price":"","df_image_link":"https:\/\/lubeteam.it\/wp-content\/uploads\/2023\/07\/Pompe-P04-removebg-preview-300x300.png","_links":{"self":[{"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/product\/5584","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/media\/5586"}],"wp:attachment":[{"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/media?parent=5584"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/product_brand?post=5584"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/product_cat?post=5584"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lubeteam.it\/en\/wp-json\/wp\/v2\/product_tag?post=5584"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}