Search
Products

HYDRO DRY UFI Recirculation Filters

HYDRO DRY UFI Recirculation Filters are specialized filter elements designed for the effective removal of free water from hydraulic oils. Using advanced FormulaUFI.H2O filter media, these elements operate by absorption, retaining up to 80% of the water present in the fluid. Ideal for off-line circuits and constant low-pressure systems, they also remove solid contaminants. Compatible with standard FRD, FOF, and FMA series housings, they represent an essential solution for preserving system life.

Download

Catalogs and technical documentation

HYDRO DRY UFI

Description

HYDRO DRY UFI Water Removal Filter Elements

The HYDRO DRY series by UFI Filters is an innovative solution dedicated to the deep purification of hydraulic fluids, with a specific focus on water removal. Free water in oil is one of the main causes of corrosion, fluid degradation, and mechanical failures; these filter elements are designed to act effectively in recirculation (off-line) circuits, filtration carts, and low-pressure lines.

Technology and Operating Principle

Hydro-Dry elements use the FormulaUFI.H2O filter media technology, which works through physico-chemical absorption. This technology ensures a high water retention capacity, removing up to 80% of free water present in the fluid.

In addition to water removal, these elements also provide solid contaminant filtration with a ratio of $beta_{21(c)} > 1.000$. However, for maximum efficiency, it is recommended to pre-filter solid particles upstream using a dedicated return line filter.

Ideal Applications and Installation

To achieve maximum water removal efficiency, Hydro-Dry elements must operate under conditions of constant flow rate and constant low pressure. This makes them ideal for use in:

  • Off-line filters (e.g. FOF series).
  • Low-pressure filters (e.g. FMA series).
  • Mobile filtration carts (e.g. UOW units).

The use of a clogging indicator calibrated at 130 kPa (1.3 bar) on the filter housing is strongly recommended, to correctly signal the need to replace the saturated element.

Range and Compatibility

The series includes several families of elements, sized to fit standard UFI Filters housings:

  • ERD Series: Compatible with FRD series filters (e.g. ERD31NWR, ERD41NWR).
  • ERF Series: Compatible with FOF series filters and UOW units (e.g. ERF34NWR, ERF44NWR).
  • IRF Series: Specific for the UOW “Green Version” filtration unit.
  • EMA Series: Compatible with FMA series filters (e.g. EMA11NWR, EMA21NWR).

Water Retention Capacity

Water retention capacity varies depending on element size and oil viscosity. For example, the ERF44NWR model can retain up to 1400 ml of water (with oil at 30 cSt), while more compact models such as EMA11NWR retain approximately 50 ml.

Technical summary table of the main characteristics of HYDRO DRY UFI Recirculation Filters.

Characteristic Value
Filter Media Technology FormulaUFI.H2O (Absorption)
Water Removal Efficiency Up to 80% of free water
Solid Filtration ß21(c) > 1.000
Available Element Series ERD, ERF, IRF, EMA
Max H2O Retention Capacity (ERF44) 1400 ml (oil 30 cSt)
Ideal Application Constant flow rate, low pressure (off-line)
Recommended Clogging Indicator 130 kPa (1.3 bar)
Housing Compatibility FRD, FOF, FMA series, UOW units

Brands

List of Manufacturers Brands

UFI FILTERS

RUOTA IL DISPOSITIVO PER VISUALIZZARE CORRETTAMENTE IL SITO