The compact integrated motor-pump units with direct drive are composed of Berarma pumps and B3-B14 hollow-shaft electric motors.
The direct coupling system significantly reduces axial dimensions as it allows the elimination of intermediate components between pump and motor (couplings, lanterns, supports…), ensuring perfect coaxiality between the two shafts and preventing dangerous misalignments that could cause abnormal wear.
The GMP units are designed for Berarma GR.05 and GR.1 pumps (displacements up to 32 cm3/rev and pressures up to 250 bar) using high-efficiency three-phase asynchronous electric motors with special flanges (rated power 0.75 – 7.5 kW).
The Motor-Pump Unit is quick and easy to install, as it can be mounted directly onto the hydraulic power pack (the use of anti-vibration mounts is recommended).
The GMP Berarma Motor Pump is an integrated direct-drive motor-pump unit, developed to reduce costs and dimensions and to simplify installation. The direct coupling eliminates joints, lanterns, and supports, ensuring perfect coaxiality between pump and motor shafts and preventing misalignments that could cause abnormal wear.
Designed for Berarma GR.05 and GR.1 pumps with displacements up to 32 cm³/rev and pressures up to 250 bar, it uses high-efficiency three-phase asynchronous electric motors with special flanges, with rated power from 0.75 kW to 7.5 kW. The unit can be mounted directly onto the hydraulic power pack; the use of anti-vibration mounts is recommended.
GMP-16: 16 cm³/rev, flow rate 23 l/min at 1450 rpm, max pressure 250 bar
GMP-20: 20 cm³/rev, flow rate 29 l/min at 1450 rpm, max pressure 250 bar
GMP-25: 25 cm³/rev, flow rate 36 l/min at 1450 rpm, max pressure 250 bar
GMP-32: 32 cm³/rev, flow rate 47 l/min at 1450 rpm, max pressure 250 bar
Available with pressure compensator:
PLP (mechanical) – PLP 05: H 20÷120 bar; L 15÷50 bar. PLP 1: H 30÷100 bar
PHP (hydraulic) – PHP 05: H 20÷250 bar; PHP 1: H 20÷250 bar
Actual displacement: 17, 21, 26, 33 cm³/rev (±3% tolerance)
Maximum operating pressure: 100, 120 or 250 bar depending on model
Inlet pressure: 0.8 ÷ 1.5 bar absolute
Maximum drain pressure: 1 bar
Speed range: 800 ÷ 1800 rpm
Direction of rotation: right-hand (clockwise viewed from shaft side)
Shaft loads: radial and axial forces not allowed
Fluids: HM ISO 6743-4; HLP DIN 51524-2; HEES ISO 15380 (FPM-Viton, Pmax 160 bar); HFD ISO 12922 (FPM-Viton, Pmax 160 bar); HFC ISO 12922 (water <40%, NBR, Pmax 100 bar, Vmax 1000 rpm, T <40°C)
Operating viscosity: 22 ÷ 68 cSt; at startup max 400 cSt
Viscosity index: minimum 100
Fluid temperature at inlet: +15 / +60 °C
Maximum contamination: 20/18/15 ISO 4406 – NAS 1638 Class 9
Recommended contamination: 18/16/13 ISO 4406 – NAS 1638 Class 7
Moment of inertia (kg·m²): 0.00012 – 0.015
Single pump weight (kg): 7.4 – 54.3
Three-phase asynchronous motors, totally enclosed, externally ventilated, squirrel-cage rotor, dynamically balanced.
Power: 0.75 – 7.5 kW
Nominal speed: 1420–1460 rpm
Efficiency depending on model: 82.5% – 90.4%
Efficiency class: IE3
Insulation class: F (IEC 34-1)
Protection rating: IP55 (EN 60529)
Nominal voltage: 230/400V ±10% 50Hz; 266/460V ±10% 60Hz
Duty type: S1 (IEC 34-1)
Cooling: bidirectional radial-blade fan, stamped sheet metal fan cover
Frame, flanges and shields: die-cast aluminum alloy, unpainted
Terminal box position: right-hand shaft side (left or top on request)
Options: thermal protection, overcurrent protection, CSA-C/US marking, voltage/frequency variants