The MP Filter Series FZH is designed to protect sensitive components in high-pressure hydraulic systems operating under harsh environmental conditions. Made of AISI 316L stainless steel, these in-line filters support a maximum working pressure of 70 MPa (700 bar) and flow rates up to 80 l/min. Suitable for vertical mounting, they provide maximum reliability for offshore applications, water filtration systems, and chemically aggressive fluids.
High-pressure stainless steel filters, specifically models FZH 012 and FZH 040, are developed for in-line installation within hydraulic circuits. The main structural components of the MP Filter Series FZH, including the head, housing, and bypass valve, are entirely made of AISI 316L stainless steel. This material configuration ensures excellent resistance in offshore applications, water systems, and in environments or with fluids that are highly corrosive. Installation of these components is designed exclusively for vertical mounting, with direct connection to system lines through hydraulic fittings.
Operating performance reaches very high standards, with a maximum working pressure of up to 70 MPa (700 bar) and a maximum flow rate of 80 l/min, supported by 1/2″ female threaded connections. Structural validation includes rigorous testing:
The internal operating principle involves fluid flow traveling from outside to inside (OUT to IN) of the filter element. Filtration is ensured by inorganic microfiber media, available with precision ratings of 3 µm, 6 µm, 10 µm, 16 µm, and 25 µm. The range offers several types of filter elements to meet specific system requirements:
Models equipped with a bypass valve feature an opening pressure calibrated at 6 bar (±10%), essential to relieve excessive pressure drop across the filter media.
Standard thermal operation ranges from -25°C to +110°C using standard NBR seals (Series A). For specific requirements, the range can be extended from -50°C to +120°C by adopting optional FPM seals (Series V, -20°C to +120°C) or MFQ seals (Series F). For continuous efficiency monitoring, the system supports differential clogging indicators available in visual (DVZ), electrical (DEZ), and electronic/visual (DLZ) versions. 5. Technical summary table
| Feature | Value |
|---|---|
| Series Models | FZH 012, FZH 040 |
| Maximum working pressure | Up to 70 MPa (700 bar) |
| Test pressure | 105 MPa (1050 bar) |
| Maximum flow rate | Up to 80 l/min |
| Material (Head, Housing, Bypass) | AISI 316L stainless steel |
| Filter Media | Inorganic microfiber 3, 6, 10, 16, 25 µm |
| Bypass Valve Setting | 6 bar ±10% |
| Seals | Standard NBR, Optional FPM, MFQ |
| Temperature Range | From -50°C to +120°C |
| Installation | Vertical, In-line |