Download
Catalogs and technical documentation
Fluidfit push-in pluggable cooling manifold with separate ways – HBUJ – Tierre
The Tierre HBUJ Fluidfit push-in pluggable cooling manifold with separate ways has a POM acetal resin body and EPDM o-ring and is designed for water, beverages, vacuum, compressed air and gases or liquids suitable with the materials: it works from -750 mmHg up to 20 bar, depending on tube and temperature, from 1 to 98 °C with air and fluids (from -20 °C with dry air).
Available product codes: HBUJ3/8-3/8G.
Fluidfit push-in pluggable cooling manifold with separate ways – HBUJ – Tierre
The Tierre HBUJ Fluidfit push-in pluggable cooling manifold with separate ways is a pluggable cooling manifold with separate ways; the detailed technical datasheet is available on request.
Fluidfit products are designed for water, food and air contact but can also be used with selected gases, vacuum and other liquids; easy actions allow the tube to be connected and released quickly, saving time and expenses. In the code, the final letter B stands for the black (metric) version and G for the grey (inch) version.
It is part of the Tierre Fluidfit fittings range, together with the Fluidfit push-in U-bend HBU and the Fluidfit push-in cooling manifold HUTT.
| Feature | Value / Specification |
|---|---|
| Fluids | Water, beverages, vacuum, compressed air, gases and liquids suitable with the construction materials |
| Working temperature | From -20 °C to 98 °C with dry air; from 1 °C to 98 °C with air and fluids |
| Working pressure | From -750 mmHg up to 20 bar, depending on the tubes and temperatures applied |
| Plastic tubes | Polyethylene (PE), polyamide (PA), polyurethane (PU), PTFE, FEP |
| Soft metal tubes | Brass, copper, mild steel, aluminium |
| Hard metal tubes | With a groove made according to the catalogue dimensions |
| Tube Ø | -20 °C | 1 °C | 25 °C | 70 °C |
|---|---|---|---|---|
| 4 mm – 5/32″ | -750 mmHg → 20 bar | -750 mmHg → 20 bar | -750 mmHg → 16 bar | -750 mmHg → 10 bar |
| 6 mm – 3/16″ – 1/4″ | -750 mmHg → 20 bar | -750 mmHg → 20 bar | -750 mmHg → 16 bar | -750 mmHg → 10 bar |
| 8 mm – 5/16″ | -750 mmHg → 20 bar | -750 mmHg → 20 bar | -750 mmHg → 16 bar | -750 mmHg → 10 bar |
| 10 mm – 3/8″ | -750 mmHg → 16 bar | -750 mmHg → 16 bar | -750 mmHg → 14 bar | -750 mmHg → 10 bar |
| 12 mm – 1/2″ | -750 mmHg → 14 bar | -750 mmHg → 14 bar | -750 mmHg → 8 bar | -750 mmHg → 6 bar |
| 15 mm | -750 mmHg → 14 bar | -750 mmHg → 14 bar | -750 mmHg → 8 bar | -750 mmHg → 6 bar |
| 22 mm | -750 mmHg → 14 bar | -750 mmHg → 14 bar | -750 mmHg → 8 bar | -750 mmHg → 6 bar |
With 10 mm – 3/8″ tube at 98 °C: 0 to 8 bar with dry air only. System performance always depends on the fittings, tubes and accessories used, and the limits given refer to systems assembled with the HCP locking clip installed.
Make sure the tube and the push-in system are the same size and cut the tube square with a proper tube cutter, such as the ETC tube cutter; the tube must be clean, without scratches, cuts or deformities. Insert it by hand up to the end stop, without tools, and pull it once without releasing the collet to check it is connected; then fit the locking clip between body and collet and push the tube in again.
To disconnect, completely eliminate the pressure from the system, remove the clip, push the collet towards the fitting body and pull the tube keeping the collet pushed. When using metallic tubing, always deburr the tube ends to avoid damaging the o-rings.
| Code | ØD1 | ØD2 | ØP | A | B | E | L1 | L2 | L3 | Weight (g) | Pcs/pack |
|---|---|---|---|---|---|---|---|---|---|---|---|
| HBUJ3/8-3/8G | G 3/8 | G 3/8 | 20.0 | 24.8 | 20.0 | 24.5 | 33.2 | 50.05 | 60.05 | 20.2 | 15 |
Dimensions refer to the technical drawing in the downloadable PDF data sheet; inch version dimensions are given as in the catalogue.
Technical data from the catalogue Tierre Fluidfit, fittings for potable water, drink dispensers and beverages, Rev. 3.0.