MP Filtri Differential Clogging Indicators accurately monitor filter element efficiency by measuring upstream and downstream pressure in hydraulic circuits. Available in visual, electrical, and electronic series, they support working pressures up to 700 bar and extreme temperatures. They are the ideal solution for pressure lines in complex industrial systems, ensuring full compatibility with mineral oils and synthetic fluids. They also offer protection ratings up to IP69K and specific certifications for explosive atmospheres.
MP Filtri Differential Clogging Indicators are technical devices used on the pressure line to verify the efficiency and wear condition of the filter element. The operating principle is based on the simultaneous measurement of pressure upstream (IN) and downstream (OUT) of the filter element itself. By detecting differential pressure, these indicators promptly signal when the critical clogging level is reached, allowing operators to schedule maintenance and prevent performance drops in the hydraulic circuit.
The MP Filtri Differential Clogging Indicators range is divided into four primary configurations to suit specific control architectures:
From a construction standpoint, standard sensors feature a brass body combined with a polyamide base. For highly corrosive environments and severe applications, models fully made of stainless steel (AISI 316L) are available. The standard mechanical interface includes special connections with G 1/2″ size.
These devices are designed for seamless integration across a wide range of filter housings, including return filters, suction filters, spin-on filters, low- and medium-pressure filters (such as LMP and LMD series), and high-pressure filters (FMP, FHP, FHM series). Stainless steel versions (DEX, DEZ, DLX, DLZ, DVX, DVZ series) are intended for high-pressure filters within the FZP, FZH, and FZX range, capable of withstanding maximum working pressures of 420 bar and peak pressures of 700 bar, specifically for the FZH series.
MP Filtri has also developed a dedicated line designed to operate safely in potentially explosive atmospheres. The DEH series features global certifications including ATEX, IECEx, EAC TR CU, and INMETRO, with protection options such as intrinsic safety (Ex ia IIC T4/T6) or flameproof (Ex d IIC T4/T6), covering temperature classes T4 (135°C) and T6 (85°C). To meet North American market requirements, configurations with UL/CSA certification (Class I Division 1, Class II Division 1) are also available.
MP Filtri Differential Clogging Indicators ensure maximum reliability by guaranteeing full compatibility with mineral oils, synthetic fluids, and water-based hydraulic fluids (HFA, HFB, and HFC) in strict compliance with ISO 2943. To ensure optimal hydraulic sealing, the components use technical elastomer seals such as HNBR, FPM, or MFQ, selectable according to the fluid and thermal conditions. Operating temperatures cover a standard range from -25°C to +110°C. Specialized variants for hazardous areas maintain excellent performance under demanding conditions, extending the range from -60°C up to +125°C.
The robust construction is also reflected in environmental protection ratings: indicators start from IP65, IP66, and IP67 specifications, reaching up to full-sealing levels IP68 and IP69K (according to EN 60529 and ISO 20653). Engineering safety margins are equally high, with burst pressures reaching 1260 bar for standard models and up to 2100 bar for specialized 700 bar stainless steel versions.
| Feature | Value |
|---|---|
| Available Types | Electrical (DE), Electrical/Visual (DL), Electronic (DT), Visual (DV) |
| Maximum Working Pressure | From 16 bar to 700 bar |
| Maximum Burst Pressure | Up to 2100 bar (for 700 bar series) |
| Body Materials | Brass, Stainless Steel (AISI 316L) |
| Seal Materials | HNBR, FPM, MFQ |
| Operating Temperatures | Standard: from -25°C to +110°C / ATEX: from -60°C to +125°C |
| Fluid Compatibility (ISO 2943) | Mineral oils, Synthetic fluids, Water-based fluids HFA, HFB, HFC |
| Protection Ratings | IP65, IP66, IP67, IP68, IP69K (EN 60529, ISO 20653) |
| Available Certifications | ATEX, IECEx, EAC TR CU, INMETRO, UL/CSA |